LIMITED WARRANTY
The DS-2B is warranted against defects in workmanship and materials for two years from date of sale.
This warranty does not apply to damage resulting from accident, misuse, or alteration nor where connected
voltage is more than 5% above the configured operating voltage, nor to equipment improperly installed or
wired or maintained in violation of this Owner’s Manual. No other written or oral warranty applies. No
employee, agent, dealer or other person is authorized to give any warranties on behalf of ASE.
The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the
product for repairs. Within the limitations of this warranty, inoperative units should be returned, freight
prepaid, to ASE, and we will repair or replace, at our option, at no charge to you with return freight paid by
ASE. It is agreed that such repair or replacement is the exclusive remedy available from ASE and that
ASE IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND
CONSEQUENTIAL DAMAGE. Some states do not allow the exclusion or limitation of incidental or
consequential damages so the above exclusion may not apply to you. The warranty gives you specific
legal rights, and you may also have other rights which vary from state to state.
AUTOMATED SYSTEMS ENGINEERING, INC.
2519 E SAINT VRAIN ST
COLORADO SPRINGS, COLORADO 80909
PHONE: 719-599-7477 FAX: 719-599-7482
Visit us on the Internet at: www.goase.com
CAUTION: Read all instructions carefully before installation.
Save this Installation Manual for future reference.
DS-2B
RAIN/SNOW SENSOR CONTROLLER
INSTALLATION MANUAL
CERTIFIED TO CAN/CSA
ENCLOSURE TYPE 3R
30 A 240V AC, 20 A 30V DC
200−240V AC 0.15 A 50/60 Hz
100−120V AC 0.15 A 50/60 Hz
RAIN/SNOW SENSOR CONTROLLER
THIS UNIT MAY BE SUPPLIED BY MORE THAN ONE BREAKER
CONTROL
INPUT
STD C22.2 NO. 14
UL STD 508
CONFORMS TO
CONTROL SWITCH
STANDBY/RESET
MANUAL ON
AUTOMATIC
CAUTION
US
ENGINEERING
DANGER
DS−2B
AUTOMATED
SYSTEMS
C
3175102
E
T
S
I
L
D
R
T
I
N
T
E
CM
E
K
Manufactured By
AUTOMATED
SYSTEMS
ENGINEERING
2519 East Saint Vrain St Colorado Springs, Colorado 80909
Page view 0
1 2 3 4

Summary of Contents

Page 1 - ENGINEERING

LIMITED WARRANTY The DS-2B is warranted against defects in workmanship and materials for two years from date of sale. This warranty does not apply to

Page 2 - General Safety Instructions

Selecting a Mounting Location for the DS-2B The interleaved grid on the top of the DS-2B is the precipitation sensor or “moisture grid.” The rubber “

Page 3 - LOAD CENTER

NEUTRAL BUS BAR15ALINE/L1NEU/L2YELLOWYELLOWLOADDS−2BLOAD CENTER30A 120VAC In, 240VAC Load, Separate Feed (Strap DS-2B for 120VAC Power) 15ALINE/L1NEU/

Page 4 - Typical Load Wiring

The relay inside the DS-2B acts as a switch. While not as convenient as directly supplying power for the load this allows you to operate the DS-2B fr